Guang Zhou PMD Machinery Parts co ltd
products
products
Home > products > Electric Parts > NG6 electromagnetic directional valve 4/2 4WE6D6X/EG24N9K4 NG6 electromagnetic directional valve 4/2 4WE6Y6X/EG24N9K4 NG6 electromagnetic directional valve German Rexroth hydraulic electromagnetic

NG6 electromagnetic directional valve 4/2 4WE6D6X/EG24N9K4 NG6 electromagnetic directional valve 4/2 4WE6Y6X/EG24N9K4 NG6 electromagnetic directional valve German Rexroth hydraulic electromagnetic

Product Details

Place of Origin: Germany

Brand Name: Rexroth

Certification: ISO

Model Number: NG6 electromagnetic directional valve 4/2 4WE6D6X/EG24N9K4 NG6 electromagnetic directional valve 4/2 4WE6Y6X/EG24N9K4 NG6 electromagnetic directional valve

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: 1

Packaging Details: wooden box

Delivery Time: 2weeks

Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability: 100

Get Best Price
Highlight:
NG6 electromagnetic directional valve 4/2 4WE6D6X/EG24N9K4 NG6 electromagnetic directional valve 4/2 4WE6Y6X/EG24N9K4 NG6 electromagnetic directional valve German Rexroth hydraulic electromagnetic

NG6 electromagnetic directional valve 4/2 4WE6D6X/EG24N9K4 NG6 electromagnetic directional valve 4/2 4WE6Y6X/EG24N9K4 NG6 electromagnetic directional valve German Rexroth hydraulic electromagnetic

brand REXROTH Valve function reversing    
Main sales regions Europe, Southeast Asia, Global Is it a cross-border export exclusive source of goods yes    
function and role Reversing type sealing material Nitrile rubber  
Pressure environment atmospheric pressure temperature environment room temperature  
Applicable Industries Metallurgy, Chemical, Mining, Industrial Drive Type Electromagnetic, Hydraulic
oil products mechanical Triple formula Unlimited supply quantity

 

NG6 electromagnetic directional valve 4/2 4WE6D6X/EG24N9K4 NG6 electromagnetic directional valve 4/2 4WE6Y6X/EG24N9K4 NG6 electromagnetic directional valve   German Rexroth hydraulic electromagnetic 0NG6 electromagnetic directional valve 4/2 4WE6D6X/EG24N9K4 NG6 electromagnetic directional valve 4/2 4WE6Y6X/EG24N9K4 NG6 electromagnetic directional valve   German Rexroth hydraulic electromagnetic 1

NG6 electromagnetic directional valve 4/2 4WE6EB6X/SG24N9K4
NG6 electromagnetic directional valve 4/2 4WE6HB6X/SG24N9K4
NG6 electromagnetic directional valve 4/3 4WE6E6X/SG24N9K4
NG6 electromagnetic directional valve 4/3 4WE6J6X/SG24N9K4
NG6 electromagnetic directional valve 4/3 4WE6M6X/SG24N9K4
NG6 electromagnetic directional valve 4/3 4WE6L6X/SG24N9K4
NG6 electromagnetic directional valve 4/3 4WE6H6X/SG24N9K4
NG6 electromagnetic directional valve 4/3 4WE6E6X/SG24N9K4
NG6 electromagnetic directional valve 4/3 4WE6G6X/SG24N9K4
NG6 electromagnetic directional valve 4/2 4WE6C6X/EG24N9K4
NG6 electromagnetic directional valve 4/2 4WE6D6X/EG24N9K4
NG6 electromagnetic directional valve 4/2 4WE6Y6X/EG24N9K4
NG6 electromagnetic directional valve 4/2 4WE6EA6X/EG24N9K4
NG6 electromagnetic directional valve 4/2 4WE6EB6X/EG24N9K4
NG6 electromagnetic directional valve 4/2 4WE6HB6X/EG24N9K4
NG6 electromagnetic directional valve 4/2 4WE6HA6X/EG24N9K4
NG6 electromagnetic directional valve 4/3 4WE6X/EG24N9K4
NG6 electromagnetic directional valve 4/3 4WE6J6X/EG24N9K4
NG6 electromagnetic directional valve 4/3 4WE6JB6X/EG24N9K4
NG6 electromagnetic directional valve 4/3 4WE6M6X/EG24N9K4

 

FQA;

Q5: What are the key precautions for installing the 4WE6 series valve?

A5: Improper installation can cause leakage, valve jamming, or shortened lifespan. Follow these rules:

 

  1. Cleanliness First: Flush the hydraulic pipeline before installation to remove metal shavings, dust, or oil residues—impurities can scratch the valve core or block ports.
  2. Port Alignment: Ensure the valve’s P/A/B/T ports match the pipeline labels (misconnection may reverse actuator movement or damage the valve).
  3. Torque Control: Tighten threaded ports or flange bolts to the manufacturer’s specified torque (e.g., M16 bolts: 25–30 N·m). Over-tightening may deform the valve body; under-tightening causes oil leakage.
  4. Solenoid Protection: Install the solenoid coil vertically (if possible) to avoid water or dust accumulation. For outdoor use, choose a coil with IP65/IP67 protection (e.g., 4WE6...-N9K4 = IP65).
  5. Orientation: Most models support horizontal/vertical installation, but avoid upside-down mounting (gravity may affect core reset, especially for spring-return valves).

Q6: Is the 4WE6 series compatible with different hydraulic oils?

A6: Compatibility depends on the sealing material (not the valve body, which is usually made of high-strength aluminum alloy or cast iron):

 

  • NBR Seals (U-suffix): Compatible with mineral oil (the most common hydraulic oil, e.g., ISO VG 32/46), water-glycol mixtures (up to 40% water), and phosphate ester fluids (low concentration).
  • FKM Seals (V-suffix): Compatible with high-temperature mineral oil, synthetic esters, and aggressive fluids (e.g., diesel, lubricating oil).

 

Do not use vegetable-based oils with NBR seals—they cause swelling and seal failure.

4. Maintenance & Troubleshooting

Q7: What regular maintenance is required for the 4WE6 series?

A7: To extend service life (typically 5,000–10,000 operating hours), perform these checks every 3–6 months:

 

  • Leakage Inspection: Check P/A/B/T port connections and solenoid coil O-rings for oil stains. Replace worn O-rings (use original manufacturer parts to ensure size/material matching).
  • Filter Cleaning: Clean or replace the hydraulic system’s suction filter and return filter (clogged filters reduce oil flow and cause core jamming).
  • Solenoid Check: Measure the coil resistance with a multimeter (DC 24V coil: 30–40 Ω; AC 220V coil: 150–200 Ω). Abnormal resistance (e.g., 0 Ω = short circuit, ∞ Ω = open circuit) means the coil needs replacement.
  • Core Lubrication: For valves used in dusty environments, apply a small amount of hydraulic oil to the core (via the valve’s oil filling port) to reduce friction.

 

Tags: